Search
Wishlist
  • Home
  • Shop
      • LCP Small Fragments Plates
      • DHS-DCS and Angle Plates
      • Bone Screws
      • LCP Large Fragments Plates
      • maxillofacial Mini Plates
      • Orthopedic Locking Plate Instrument Set
      • Locking Distal Radius Plates
      • Hip Prosthesis
      • Orthopedic Trauma Plate Instrument Set
  • About us
  • Contact us
  • Exhibition View
0 items $0.00
0 items $0.00
Menu
  • Home
  • Shop
  • About us
  • Contact us
  • Exhibition View
Create your first navigation menu here and add it to the "Main menu" location.
Home Maxillofacial Mini Plates Strut Plate Craniomaxillofacial Introduction
Straight Plate Mandible Introduction
Straight Plate Mandible Introduction
Back to products
T Plate Craniomaxillofacial Introduction
T Plate Craniomaxillofacial Introduction
Hot
Click to enlarge

Strut Plate Craniomaxillofacial Introduction

Compare
Add to wishlist
SKU: FS-136 Category: Maxillofacial Mini Plates
  • Description
  • Reviews (0)
  • Shipping & Delivery
Description

 

The aim of surgical fracture treatment with Strut Plate Craniomaxillofacial is to reconstruct the bony anatomy and restore its function. According to the AO, internal fixation is distinguished by anatomical reduction, stable fixation, preservation of blood supply, and early, active mobilization.

Strut Plate Craniomaxillofacial Features and Benefits
Wide offering of Strut Plate geometries, sizes, and strengths
Seven screw diameters to choose from: 1.5 mm, 2 mm, 2.5 mm, 2.8 mm, 2 mm Locking, 2.5 mm Locking and 2.8 mm Locking
Rounded edges on plates for less irritation to soft tissue, where applicable
Reduced plate/screw profile, where applicable
Emergency screws available for each screw diameter
Plates and Screws are made from pure Titanium
Standardized instrumentation
locking plate increases construct stability, decreases risk of screw back-out and subsequent loss of reduction. It also reduces the need for precise anatomic plate contouring and minimizes the risk of stripped screw holes.
Strut Plate Craniomaxillofacial Indications
Plate is intended for use in selective trauma of the midface and craniofacial skeleton, craniofacial surgery, reconstructive procedures, and selective orthognathic surgery of the maxilla and chin.
Strut Plate Craniomaxillofacial Contraindications
Plate is contraindicated for use in areas with active or latent infection or insufficient quantity or quality of bone.
Strut Plate Craniomaxillofacial Precautions
Confirm functionality of instruments and check for wear during reprocessing. Replace worn or damaged instruments prior to use.
It is recommended to use the instruments identified for this plate.
Handle devices with care and dispose worn bone cutting instruments in a sharps container.
Always irrigate and apply suction for removal of debris potentially generated during implantation or removal.
Strut Plate Craniomaxillofacial Warnings
Plate can break during use (when subjected to excessive forces). While the surgeon must make the final decision on removal of the broken part based on associated risk in doing so, we recommend that whenever possible and practical for the individual patient, the broken part should be removed. Be aware that implants are not as strong as native bone. Implants subjected to substantial loads may fail.
Instruments, screws and cut plates may have sharp edges or moving joints that may pinch or tear user’s glove or skin.
Take care to remove all fragments that are not fixated during the surgery.
While the surgeon must make the final decision on implant removal, we recommend that whenever possible and practical for the individual patient, fixation devices should be removed once their service as an aid to healing is accomplished. Implant removal should be followed by adequate post-operative management to avoid refracture.
Strut Plate Craniomaxillofacial General Adverse Events
As with all major surgical procedures, risks, side effects and adverse events can occur. While many possible reactions may occur, some of the most common include: Problems resulting from anesthesia and patient positioning (e.g. nausea, vomiting, dental injuries, neurological impairments, etc.), thrombosis, embolism, infection, nerve and/or tooth root damage or injury of other critical structures including blood vessels, excessive bleeding, damage to soft tissues incl. swelling, abnormal scar formation, functional impairment of the musculoskeletal system, pain, discomfort or abnormal sensation due to the presence of the device, allergy or hypersensitivity reactions, side effects associated with hardware prominence, loosening, bending, or breakage of the device, mal-union, non-union or delayed union which may lead to breakage of
the implant, reoperation.

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Strut Plate Craniomaxillofacial Introduction” Cancel reply

Your email address will not be published. Required fields are marked *

Shipping & Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.

Related products

Hot
Compare
Quick view
Add to wishlist
Add to Quote

Adaption Plate Mandible Introduction

Maxillofacial Mini Plates
Hot
Compare
Quick view
Add to wishlist
Add to Quote

X Plate Craniomaxillofacial Introduction

Maxillofacial Mini Plates
Hot
Compare
Quick view
Add to wishlist
Add to Quote

Straight Plate Mandible Introduction

Maxillofacial Mini Plates
Hot
Compare
Quick view
Add to wishlist
Add to Quote

Frame Plate Rectangle Craniomaxillofacial Introduction

Maxillofacial Mini Plates
Hot
Compare
Quick view
Add to wishlist
Add to Quote

L Plate Angle Craniomaxillofacial Introduction

Maxillofacial Mini Plates
Hot
Compare
Quick view
Add to wishlist
Add to Quote

Crescent Plate Mandible Introduction

Maxillofacial Mini Plates
Hot
Compare
Quick view
Add to wishlist
Add to Quote

Angle Reconstruction Plate Mandible Introduction

Maxillofacial Mini Plates
Hot
Compare
Quick view
Add to wishlist
Add to Quote

Y Plate Craniomaxillofacial Introduction

Maxillofacial Mini Plates
logo-11

FS-Ortho is a leading name in the field of manufacturing. We offer a full range of Orthopedic implants bone plates , Bone screws ,hip prosthesis implants and Orthopedic instruments. Our quality complies with ISO9001, ISO 13485, CE Mark Standard

Useful Links

  • Home
  • Products
  • About us
  • Contact Us
  • Exhibition View

Our Categories

  • LCP Small Fragments Plates
  • LCP Large Fragments Plates
  • Locking Distal Radius Plates
  • DHS-DCS and Angle Plates

Contact us

  • info@fsortho.co.id
  • +92 333-8276905
  • +92 300-4664047
  • +62 813-3333-9024
  • F.S ORTHO Ganjianwali khurd Sialkot 51310 Pakistan
  • PT. FORTIS STAR ORTHO kota Madiun

Live Visitor

Flag Counter
Facebook Twitter Instagram

©2023. FSORTHO . All Rights Reserved.

Development by : CREATE WEB SOLUTION

Start typing to see products you are looking for.
Shop
Wishlist
0 items Cart

WhatsApp us